27th September 2024 14:23:56
AAQMS
Home | AAQMS

The Best of the Best in One Package:
The AQSync Air Quality Monitoring Station

 

  • FEM-quality absorbance measurements for O3, NO2, and NO.
  • NDIR absorbance for CO2.
  • Optical particle counter with sheath flow and heated inlet for PM1, PM2.5, and PM10.
  • Amperometry for CO.
  • ​Photoionization for total VOCs.
  • Sonic anemometry and weather data.
  • ​Data access and instrument control via the Cloud.
  • Power-stingy requirements enable options for powering with battery or solar panel.

Expand the possibilities with the AQSync

 

  • Extend air quality monitoring to sparse data areas or remote locations
  • Set up a drive-by calibration station for your sensor-based mobile AQ monitoring program
  • Place a network of AQSync instruments at schools or other public sites to monitor and map air pollution
  • ​Upgrade/augment existing AQ monitoring capabilities

 

 

 

Detailed Specifications

Instrument and Sensor Specifications
(per manufacturer)

Ozone (O3)

Measurement Method: UV Absorbance at 254 nm

Instrument: 2B Technologies Model 108-L (FEM)

Linear Range: 0-100,000 ppb

Precision: 1.5 ppb or 2% of reading for 10-s avg

Accuracy: 1.5 ppb or 2% of reading

Response Time: 4 s for 2-s avg, 20 s for 10-s avg

Nitrogen Dioxide (NO2)

Measurement Method: Direct Absorbance at 405 nm

Instrument: Based on 2B Tech Model 405 nm NO2/NO/NOx Monitor (FEM approval pending)

Linear Range: 0-10,000 ppb

Precision: 0.5 ppb

Accuracy: 2 ppb or 2% or reading

Response Time 20 s

Nitric Oxide (NO)

Measurement Method: Oxidation to NO2 with O3
followed by Absorbance of NO2 at 405 nm

Instrument: 2B Tech Model 405 nm NO2/NO/NOx Monitor

Linear Range: 0-2,000 ppb

Precision: 0.5 ppb

Accuracy: 2 ppb or 2% of reading

Response Time: 20 s

Particulate Matter (PM1, PM2.5, PM10)

Measurement Method: Optical Particle Counter, right angle light scatter detection with sheath flow and heated inlet

Instrument: Met One Instruments Model 83214

Range: 0-320,000 particles per liter

Minimum Particle Size: 0.3 μm

Accuracy: 10%

Response Time: minimum 1 s

 
Carbon Dioxide (CO2)

Measurement Method: Non Dispersive Infrared (NDIR) Absorbance with Auto-Zeroing

Instrument: PP Systems CO2 Gas Analyzer, Model SBA-5

Linear Range: 0-1,000 ppm

Precision: 1 ppm

Accuracy: 5 ppm

Response Time: 10 s

Carbon Monoxide (CO)

Measurement Method: Amperometry

Linear Range: 0-50 ppm

Sensor: Alphasense CO-A4

Precision: 0.02 ppm

Accuracy: 0.1 ppm

Response Time: 20 s

 

Total VOCs

Measurement Method: Photoionization Detector (PID)

Sensor: ION Science Mini-PID2 HS

Measurement Range: 0 to 3 ppm

Sensitivity: > 600 mV per ppm

Minimum Detection Limit: 0.5 ppb

Response Time: < 12 s

System Specifications

Weight 54.5 lb, 24.8 kg
(varies with modules chosen)
Size 25.5 x 25.5 x 10.3 in (65 x 65 x 26.2 cm); height with weather station is 49 in (124.5 cm)
Power 35 watt (53 watt max during warmup)
(varies with modules chosen)
Data Transmission Cellular or WiFi to the Cloud; Ethernet option
Sample Flow Rate ~4 L/min
(varies with modules chosen)
​*SO2 sensor available as an option.